Chapter 16 Engineering Setup
342
Setup Relating to Router Interface and Tally
1
In the Router/Tally>Wiring menu, press [New].
The New menu appears.
2
With a knob or menu operation, set the destination.
When switcher inputs and outputs are connected to the router in a group,
you can specify the start and end destination addresses.
Destination From: Specify the start destination address for the wiring
configuration.
Destination To: When the wiring configuration is multiple, specify the
end destination address. For a single wiring connection, this setting is
not required.
Destination Level: Specify the destination level of the wiring
configuration.
3
Set the source.
Source From: Specify the source start address for the wiring
configuration.
Source Level: Specify the source level for the wiring configuration.
4
Press [Execute].
This makes the wiring setting according to the specifications in steps 2 and
3.
Changing the wiring settings
Use the following procedure.
1
In the Router/Tally>Wiring menu, press [Modify].
The Modify menu appears.
Knob Parameter Adjustment Setting values
1 Destination (From) Destination start address 1 to 1024
2 Destination (To) Destination end address From start address to
1024
3 Destination (Level) Destination level 1 to 8
Knob Parameter Adjustment Setting values
4 Source (From) Source start address 1 to 1024