Commissioning
If your industrial truck is equipped with a Euro
battery male connector, make sure that the
voltage index pin is in the correct position. The
set voltage can be read through a display win-
dow (1).
WARNING
Risk of accident
Risk of injury from crushing zone and shearing zone
WARNING
Risk of short circuit
Do not clamp or crush battery cables.
Before starting each shift, check that the bat-
tery lock is in good working order and that it
functions correctly.
Before using the battery for the first time, a
proper commissioning procedure must be per-
formed. If the battery was obtained separately
to the industrial truck, check the following:
The nominal voltage
The minimum required weight
The model and design of the battery male
connector fitted
The minimum required cross-section and
the connection type of the battery cable
CAUTION
Danger of damage to property
Observe the information and guidelines from the bat-
tery manufacturer.
Permitted batteries
Only batteries with trays constructed in ac-
cordance with EN1175-1 may be used for op-
eration of the industrial trucks.
Battery commissioning
Proper commissioning must be performed if