Place of attachment and retrofitting
Attach the safety headlight to the highest pos-
sible part of the industrial truck using the as-
sembly material supplied. During installation,
ensure that the safety headlight is located
within the truck contour. Because this safety
headlight can be fitted to industrial trucks with
a wide range of different designs, no precise
specifications can be provided here regarding
the ideal place of attachment. Raising the load
or the driver's cab can cause the safety head-
light to be temporarily covered. Careful selec-
tion of the place of attachment can reduce this
sometimes unavoidable situation to a mini-
mum. The supplied supports must be used
wherever possible.
The tilting support mounting must be used to
adjust the safety headlight so that the light
beam is projected onto the ground approxi-
mately 4 m in front of or behind the industrial
truck. When adjusting the safety headlight, the
front edge of the industrial truck or load must
be considered. Selecting a place of attach-
ment that is high up on the truck maximises
the tilt angle of the safety headlight and en-
sures that pedestrians and oncoming vehicles
are dazzled by the light beam as little as pos-
sible.
Technical data
Operating voltage 12 – 100 V
Power consumption 5 W
Current draw 0.2 A at 24 V
Service life >20,000 hours
Protection class IP68 - IP69K
Operating temperature -40°C - +85°C
Acoustic alarm
Acoustic alarms can be issued automatically if
dangerous situations may arise between hu-
mans and machines during a racking work
procedure. This ensures that other people are
Special equipment
7
Acoustic alarm
1475231 804 2502 EN - 04/2020