EasyManua.ls Logo

Sun Microsystems Sun Fire V890 - Reference for Environmental Requirements

Sun Microsystems Sun Fire V890
227 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B System Specifications 173
Reference for Environmental
Requirements
The operating and non-operating environmental requirements for the system are
as follows.
Parameter Value
Operating
Temperature 5˚C to 35˚C (41˚F to 95˚F)—IEC 68-2-1, 68-2-2
Humidity 20% to 80% RH, noncondensing; 27 ˚C max wet bulb—IEC 68-2-2,
68-2-3
Altitude 0 to 3000 meters (0 to 10,000 feet)—IEC 68-2-40, 68-2-41
Vibration:
Deskside
Rackmounted
0.0002 g
2
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
0.00015 g
2
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
Shock:
Deskside
Rackmounted
4 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
3 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
Declared Acoustics 6.7 bels dB(A) operating, 7.6 bels dB(A) at ok prompt
Non-Operating
Temperature -20˚C to 60˚C (-4˚F to 140˚F)—IEC 68-2-1, 68-2-2
Humidity 95% RH, noncondensing at 40˚C—IEC 68-2-2, 68-2-3
Altitude 0 to 12,000 meters (0 to 40,000 feet)—IEC 68-2-40, 68-2-41
Vibration:
Deskside
Rackmounted
0.002 g
2
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
0.0015 g
2
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
Shock:
Deskside
Rackmounted
15 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
10 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
Handling Drops 50 mm—IEC 68-2-31
Threshold Impact 1 m/s—SUN 900-1813