IGNITION AND ELECTRICAL 3-27
NEUTRAL SWITCH
09930-99320: Digital tester
Tester range: (Continuity)
1. Disconnect neutral switch lead wire.
2. Check continuity/infinity between Yellow/Green and Brown
lead wire while operating the shift lever or remo-con handle.
Neutral switch function:
If out of specification:
•1st
Check switch position adjustment, readjust if necessary.
• 2nd
Replace neutral switch.
NOTE:
After installing neutral switch, check for proper correct function
by operating remo-con handle or shift lever.
STARTER MOTOR RELAY
09930-99320: Digital tester
Tester range: (Continuity)
1. Remove the plate a by sliding it upward.
2. Remove CDI unit b.
3. Pull out relay c from electric parts holder, then disconnect
starter motor relay from wire.
4. Check continuity between terminal 1 and 2 each time 12 V
is applied. Connect positive + side to terminal 4, and nega-
tive - side to terminal 3.
Starter motor relay function:
Shift position Tester indicates
Neutral Continuity
Forward Infinity
Reverse Infinity
Forward
Neutral
Reverse
12 V power Continuity
Applied Yes
Not applied No
Be careful not to touch 12 V power supply wires to
each other or with other terminals.
CONT
12 V