RUN EXCITE: Service & Maintenance Manual - rev. 1.5
9.3. SERVICE MENU CONFIGURATION
The configuration procedure is invoked when the machine is in standby mode, using a different
, 700 and 900 models.
• Accessing configuration of 500 models
eys. The following prompt appears on the LED
display:
o access the procedure, type in the password 2501 which protects against unauthorized access and
press “Enter” to confirm. To enter the pass or decrease the displayed value using the
and ↓ keys, or use the +/- GOAL keys to scroll through and modify the individual digits.
At this point there are two options available:
= Tech Config
meric key ↑ to access the menu for configuring technical parameters; the machine display
ill begin showing the current configuration, structured as in the diagram below:
Accessing configuration of 700 and 900 models
imultaneously press the keys 369. The following prompt appears on the display:
ENTER PASSWORD:
To access the procedure, type in the password 2501 which protects against unauthorized access and
press the “Enter” key to confirm. At this point there are two options available:
1 = Tech Config
2 = Troubleshooting
Press numeric key 1 to access the menu for configuring technical parameters; the machine display
will begin showing the current configuration, structured as in the diagram below:
procedure for the 500
Simultaneously press the ENTER, ↑, CLEAR k
ENTER PASSWORD:
T
word, increase
↑
↑
↓ = Troubleshooting
Press nu
w
•
S
Page 9.13