RUN EXCITE: Service & Maintenance Manual - rev. 1.5
To scroll through the list of available functions, press the + or – speed keys to display the next or
previous item. Confirm the choice by pressing ENTER. To cancel the operation, press the CLEAR
key for a few seconds.
The tests are divided into two groups: Automatic and Manual. The machine prompts for a choice
immediately upon accessing the troubleshooting menu.
6.1.1. AUTOMATIC TESTS
The tests grouped under this section conduct checks on the machine’s operation in a fully automatic
manner. After selecting the desired test using the + and – speed keys, press ENTER to initiate the
test and then await the result. Press ENTER again to continue, or press the CLEAR key for a few
seconds to return to the higher menu level. The various tests are described below.
6.1.1.1. I2C Device Test
The I2C Devices test checks the communication following the 32K and 256K memories and the
operation of the OwnZone receiver only for what concerns the data reception function, but not the
detection of the heart rate signal. The test can have two outcomes:
“Test Successful, press Enter to continue”: Signifies that data packets were successfully
transmitted and received between the I2C devices and the digital plan board.
“OwnZone error, press Enter to continue”: Signifies that the transmission and/or reception
of data packets between the OwnZone and the digital plan board was not completed
successfully.
“EEPROM Error, press Enter to continue”: Signifies that the digital plan board has
communication problems with the memories.
6.1.1.2. UpDown Test
The UpDown test checks whether the number of pulses output by the encoder corresponds to the
values of the UpDown table stored in the low kit. During the test, the machine incline is moved
from 0 to 15% and then back to 0. Each incline position is converted into a number of pulses and
compared with the value in the UpDown table.
Two messages appear during the test:
- “Incline =15%”: This message appears during the upward movement, when the machine incline
reaches 15%.
- “Incline =3%”: This message appears during the downward movement, when the machine
incline reaches 3%.
The test can have two outcomes:
“DC Error (Up/Down), press Enter to continue”: The message indicates that the values do
not correspond. The specific message (Up or Down) indicates whether the error occurred during
the upward (Up) or downward (Down) movement of the test.
“Test Successful, press Enter to continue”: This message indicates that the test was
completed without errors.
Page 6.3