Page 65 of 957.10-00110b_en
Maintenance
10�1�1 Replacement of top part of mixing arms
1. Unscrew the adjustment screws (6 & 11) far enough for the spring (8) and plug bolt (4) to
be pulled out.
2. Remove the insertable sheet (10).
3. Remove the feather key (7) by moving the adjusting rings (5 & 9) to the side.
4. Pull the top part of the mixing arm (14) out of the rotor case (12).
To reinsert mixing arm parts, reverse the above procedure.
10�1�2 Replacement of outer scraper arm
See 10.1.1 "Replacement of top part of mixing arms"