Warranted Characteristics
Table 1-8: Warranted Characteristics - Horizontal System
Name
Timebase
Accuracy
•
(Non-Store)
Sweep
Linearity
•
(Non-Store)
Displayed
Trace
Length
(Non-Store)
Storage
Sweep
Resolution
Differential
Accuracy
b
EXT
CLK
Maximum
Input
Voltage
Input
Impedance
Description
Magnifier
Setting
Measurement
Accuracy
X1
( +
15
° C
to
+35
°
C)
±3%
X10
Magn
( +
15
° C
to
+35
°
C)
±4%
X50
Magn
( +
15
° C
to
+35
°
C)
±5%
X1
(
+0
° C
to
+40
°
C)
±4%
X10
Magn
(
+0
° C
to
+40
°
C)
±5%
X50
Magn
(+0
°C
to
+40
°C)
±8%C
Magnifier
Setting
Measurement
Accuracy
X1
5%
X10
8%
X50
9%
~1
0
Divisions
400
Dots
per
Division
Graticule
indication
of
time
cursor
difference
is
within
±2%
of
readout
value
(DC+
peak
AC)
25
V
or
25
V
p-p
AC
at
100
kHz
or
less
(See
Figure
1-1)
1
Mn±
1 o %
parallel
25
pF
±
2.5
pF
• Sweep accuracy and Sweep Linearity applies over the center eight divisions. Exclude
the first 50 ns
of
the sweep
for
X10 magnified sweeps and the first 100 ns for
XSO
magnified sweep. Exclude beyond the 10th division
of
the unmagnified sweep.
" Measured over center eight divisions.
c Max. 10 nsec/div
Revised 3/93
1 -
15