Analyzing waveforms Set up I2C search parameters
Search for SS Active
Search for data
The data type options available in Search F or Data are Number of Bytes, Data Format, and Data Value.
Select the Data Format from the drop-down list. Click Edit to enter the data value. Click Setup to
adjust the logic thresholds.
Set up I2C search parameters
After setting up an I2C bus, go to the Analyze menu, select Search, and then select the Bus trigger type;
then open the Congure tab.
Overview
Use th
e controls to set up the I2C Bus parameters.
DSA/DPO70000D, MSO/DPO/DSA70000C, DPO7000C, and MSO/DPO5000 Series 325