5 First steps
40 0970 4020 en 01 testo AG
5. Position the probes precisely at their measurement points to
check the radio link.
6. Briefly press the connect key
on the rear of the probe.
If the LED at the probe flashes
• green, a radio link exists.
• red, no radio link exists.
If no radio link to the Saveris base exists even after a
change of location of the probe, connect a router to the
Saveris base; see Integrating Saveris router (optional),
page 52.
Pos: 65 /TD/Erst e Schritte/testo Saver is/05a Saveris- Software installier en @ 0\mod_1188478151968_ 79.doc @ 2991
5.9. Installing Saveris software
Administrator rights are required to install programs and
drivers under Windows
®
2000 SP4, XP and Vista.
1. Insert CD with Saveris software in the CD-ROM drive.
If the installation program does not start automatically, open
Windows Explorer and start the
Setup.exe file on the product
CD.
During the installation of the Saveris software the
licence-free database system Microsoft SQL Server
2005 Express is installed – if this is not already present.
The database is protected by the so-called "sa
password", the password for the database
administrator, to prevent unintended changes to the
database.
If a software exists on the computer used that uses the
SQL Server 2005 Express and a password was already
set when this was installed, you then require this sa
password to be able to perform the installation of the
Saveris software.
2. Follow the directions of the installation wizard.
The USB driver for the connection of the Saveris base
is installed with the Saveris software.
If the Saveris base is not recognized as new hardware
when connected to the computer, the USB driver must
be manually installed.