Page 5-12 Document Ref 905675-001 Rev 2
Set Up Modes WWC T1 Set Up & Maintenance Manual
Issue B
Y IS VALID ADDRESS
(CONT.)
Display Explanations/comments
HoSE X
AFM Address menu.
rIGHt
A valid address is displayed i.e. y is within the range 1 to 12.
AF y
Each AFM must be programmed according to the following
procedures. Failure to do so will result in error message
4 3 (pulser not connected) when a delivery is attempted.
Press 7 to save and continue.
oPEn
Open Seal menu (only if seal is closed).
S E A L This request will display for approx. 3 seconds.
AF y
Press 7 to open the seal and continue.
FUEL
Fuel Type menu (only if seal is open).
GAS
The current setting is displayed. Press 9 to change the
AF y
parameter (Gas, Diesel etc.)
Press 7 to save and continue.
voLU
Volume Unit menu.
LItEr
The current setting is displayed. Press 9 to change the
AF y
parameter (Liter = standard for Europe, or Gallon)
Press 7 to save and continue.
coMP
Compensation Mode menu (with current setting displayed).
2
Press 9 to change the parameter to:-
AF y
2 (standard configuration)
3 (temperature correction, future uses - requires special AFM
hardware)
Press 7 to save and continue.
c_bld
Compensation Factor menu (with current setting displayed).
8000
Press 8 to select the parameter.
AF y
Press 9 to change the selected parameter.
The value is displayed in Hex notation (the standard 0x8000H is
equivalent to 100,000 in decimal).
Note : Do not change the factor until exact measurements and
calculations have been done to determine the actual divergence
of the meter.