33. CHANGING THE SETTINGS
260
Atmospheric correction factor is calculated and set using the entered values of
the temperature and air pressure. Atmospheric correction factor can also be
entered directly.
"Illum. hold" and "Guide light" are displayed only for the ES Series.
Items set, options, and input range (*: Factory setting)
The screen will be displayed only when "Illum. hold " is set to "Guide" and the
cursor is on "Guide".
Item set and option (*: Factory setting)
Mode (Distance measurement
Mode)
Fine “r”*, Fine AVG (Setting: 1 to 9 times),
Fine “s”, Rapid "r", Rapid “s”, Tracking
Reflector Prism*, Sheet, N-prism (reflectorless)
PC (Prism constant) -99 to 99 mm ("Prism" is selected: 0*,
"Sheet" is selected: 0*)
Illum. hold Laser (laser sight)*, Guide (Guide light)
Temp. (Temperature) -35 to 60°C (15*)
Air pressure 500 to 1400hPa (1013*)/
375 to 1050mmHg (760*)
ppm (Atmospheric correction
factor)
-499 to 499 (0*)
The Guide light (Brightness
level of the guide light)
1 to 3 (3*)
EDM
Mode
Reflector
PC
Illum.hold
Guide light
: Fine r
: Prism
: 0
: Guide
: 3