User's Guide ______________________________________________________________________
118 _________________________________________________________________ M211296EN-A
Messaging Parameters
The following sections describe parameters used to control messaging
through telemetry and local communication devices.
NOTE
Even if all listed parameters are present in AWS330 system, only those
settings that have suitable hardware available are usable with that
particular system.
Message Intervals
Intervals to create different messages for telemetry are defined by the
following parameters:
1011-019
Figure 68 Setting Message Interval
Table 23 Message Interval Parameters
Message Set Name Parameter Name Use
CSV / OC MessageDispatcher csv_interval Message interval [s]
SMS MessageDispatcher sms_interval Message interval [s]
Table MessageDispatcher table_interval Message interval [s]
NOTE
Bear in mind the constraints set by the media and the protocol used.
Generally, intervals under 1 minute should be used only for local
connections, that is, serial line or Ethernet/LAN.