EasyManuals Logo

Vaisala AWS330 User Manual

Vaisala AWS330
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
User's Guide ______________________________________________________________________
140 _________________________________________________________________ M211296EN-A
6. In the Command wait timeout (ms) field, enter a value in
milliseconds that specifies for how long AWS Client will wait for
the logger to respond when AWS Client sends a requests over the
serial line connection. If the request, for instance, a log file
download, succeeds within the timeout, a success message is
displayed. If the request fails, a failure message is displayed
instead, and you have the option to try again at a later time. Factors
such as the current load on the logger, delays in the connection, and
the response length affect whether or not the timeout will expire
during a request.
7. From the COM port field, select the serial port to be used on your
computer and the line parameters. The default line parameters for
the QML logger are 9600 bps, No parity bit, 8 data bits, 1 stop bit,
No flow control.
8. If you are using a modem to connect to the QML logger, enter also
the Telephone number to dial, the modem Initialization and Dial
commands, and the Hangup command. For instance, in the
Initialization command field, you could enter "ATE\rATX1";
that is, multiple AT commands separated by a "\r". Likewise, in the
Dial-up command field, you could enter ATDT123456; that is, an
AT command immediately followed by a phone number.
9. Save your settings and return to the Address Book window by
selecting Save.
TCP/IP Socket Connections
To add an Address Book entry for a TCP/IP socket connection, proceed
as follows:
1. On the Settings menu, select Address Book.
2. Select New. The fields for selecting new connection parameters are
displayed.
3. From the Type list, select Client socket or Server socket as the
connection type. The fields for selecting the TCP/IP connection
parameters, shown in Figure 84 on page 141, are displayed.