EasyManuals Logo

Vaisala AWS330 User Manual

Vaisala AWS330
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Chapter 4 _______________________________________________________________ Installation
VAISALA_______________________________________________________________________ 77
Installing Sensor Support
Sensor support is mounted on the mast and serves for mounting several
sensors. In AWS330, a suitable installation height to the mast is
1.8 meters.
Install the sensor support as follows:
1. Mount the sensor support to the mast using a U-bolt (number 2 in
Figure 37 below) and the mounting plate (6).
2. Use a spirit level to verify that the arm is level.
1012-181
Figure 37 Mounting Sensor Support
The following numbers refer to Figure 37 above:
1 = Sensor support
2 = U-bolt
3 = Nut M8 DIN934 A4, 4 pcs
4 = Washer A6.4 DIN125 A4, 10 pcs
5 = Screw M6x16 DIN912 A4, 10 pcs; use Allen key 5 mm
6 = Mounting plate
7 = Spring washer B8 DIN127 A4, 4 pcs

Table of Contents