Equipment Grounding and Lightning 
Protection 
WARNING 
Consult the local electricity professionals for the local grounding 
requirements. The customer is responsible for supplying grounding 
cables, rods, clamps, power cables, long distance signal cables, and 
conduits for cables. 
 
With mast installations, equipment grounding and lightning 
protection must be done separately. The main principles are as follows: 
-  Proper equipment grounding is required for personnel safety and for 
equipment protection. A piece of equipment is grounded by 
connecting its metal structures and electrical equipment to an external 
buried ground rod. Individual site requirements may dictate changes in 
the procedures described in this manual. Changes are permissible as 
long as protection equivalent to the original requirements is provided 
for the system. 
WARNING 
Failure to provide proper grounding may result in personnel injury or 
death from electrical shock and may severely damage the equipment. 
 
WARNING 
Lightning protection is required to prevent personnel injury and 
equipment damage due to direct lightning strikes and lightning-induced 
current surges. 
 
-  The materials used in the manufacture of the grounding systems must 
be chosen to prevent them from forming an electrolytic couple. It is 
recommended that you use copper (Cu).