Chapter 5 __________________________________________ Software Configuration and Operation
VAISALA______________________________________________________________________ 121
Alarming Protocols
Protocols used to transmit alarm messages through telemetry and local
serial links are selected as follows:
1011-021
Figure 70 Selecting Alarming Protocol
Alarm messages are divided into two types: meteorological and
technical. Meteorological alarms are based on observed values, for
example, air temperature. Technical alarms are triggered by changes in
system status, for example, a broken sensor.
Messaging configuration is done per type.
Table 25 Alarm Message Parameters
Alarm Type Set Name Parameter Name Use
Meteorological MessageDispatcher alrmet_to_com0 Send to COM0 (RS232)
Meteorological MessageDispatcher alrmet_to_email Send using eMail
Meteorological MessageDispatcher alrmet_to_ftp Send using ftp
Meteorological MessageDispatcher alrmet_to_local Send to Data Out (RS485)
Meteorological MessageDispatcher alrmet_to_sms Send using SMS
Meteorological MessageDispatcher alrmet_to_socket Send using TCP-socket
Technical MessageDispatcher alrtech_to_com0 Send to COM0 (RS232)
Technical MessageDispatcher alrtech_to_email Send using eMail
Technical MessageDispatcher alrtech_to_ftp Send using ftp
Technical MessageDispatcher alrtech_to_local Send to Data Out (RS485)
Technical MessageDispatcher alrtech_to_sms Send using SMS
Technical MessageDispatcher alrtech_to_socket Send using TCP-socket
Technical MessageDispatcher alrtech_list Create list of technical
alarms
Settings: 0 = Alarm is not sent, 1 = Alarm is sent.