Alarms
The following parameters provide limits for preconfigured alarms:
1012-168
Figure 81 Setting Alarm Limits
Table 35 Alarm Limit Parameters
Monitored Value Unit Alarm Set Name Limit Type Default Limit
Air temperature instant °C High limit TA_AlarmHigh high_limit 40
Air temperature instant °C Low limit TA_AlarmLow Low_limit 0
Wind speed max 10 min m/s High limit WS_Alarm high_limit 20
Precipitation sum 1 hour mm High limit PR_Alarm high_limit 20
Datalogger temperature °C High limit None Fixed +65 °C 65
Datalogger temperature °C Low limit None Fixed -65 °C -65
Datalogger supply voltage VDC Low limit DC_Alarm Low_limit 10.5
To enable transmission of alarm message with the selected media, use
one of the options described in Table 25 on page 121.