User's Guide ______________________________________________________________________  
130 _________________________________________________________________ M211296EN-A 
Local Serial Line 
Observation and alarm messages can be sent over local RS232 and 
RS485 lines. The following line parameters are fixed in AWS for both 
COM0 (RS232) and Data Out (RS485): 
Table 30  Serial Line Parameters 
Parameter Value 
Speed 9600 bps 
Data bits  8 
Stop bits  1 
Parity None 
 
Use the following parameters to control which messages are sent to local 
serial lines (see Table 24 on page 119 and Table 25 on page 121): 
- csv_to_com0 
- csv_to_local 
- table_to_com0 
- table_to_local 
- sms_to_com0 
- sms_to_local 
- alrmet_to_local 
- alrmet_to_com0 
- alrtech_to_local 
- alrtech_to_com0 
Set interval of the selected observation message type by (see Table 23 on 
page 118): 
- csv_interval 
- sms_interval 
- table_inte
rval