Chapter 5 __________________________________________ Software Configuration and Operation
VAISALA______________________________________________________________________ 123
Table 26 TCP-Socket Connection Parameters
Set Name Parameter Name Use
VCOM0 host1 Name or IP address of the Data Acquisition
Server
VCOM0 port1 TCP port in Data Acquisition Sever
VCOM0 retry1 Number of retries for connecting
VCOM0 netif1 Network interface to use
(1
(1
Preset at factory. Do not modify.
To enable sending messages over TCP-socket, use the following
parameters described in Table 24 on page 119 and Table 25 on page 121:
- csv_to_socket
- sms_to_socket
- table_to_socket
- alrmet_to_socket
- alrtech_to_socket
Set the interval of the selected observation message type by (see Table 23
on page 118):
- csv_interval
- sms_interval
- table_interval