Chapter 7 ___________________________________________________________ Troubleshooting 
 
VAISALA______________________________________________________________________ 217 
10.  To send the AT commands manually, the command interface of the 
modem can be directly accessed. To control the modem directly, 
open the service connection to the QML logger. With AWS330, the 
device is connected to the second DSI486 communication port at 
the module place MOD1, type open DSI486_0_1. To terminate this 
operation, type close. While the direct connection to the modem or 
sensor is open, any automatic operation through the connected port 
is blocked.  
11.  It is impossible to have default parameters that would work 
everywhere with all the different network infrastructures. If the 
default parameters do not seem to work, try to find out the correct 
parameters by establishing a manual connection between the 
weather station and the data collection system. Do this by, for 
example, using a PC terminal program. Also note that the default 
parameters are seldom optimal, for example, in minimizing the 
connection time.