Appendix B ______________________________________________________ Calculation Formulas
VAISALA______________________________________________________________________ 277
P
wi
(t) is calculated with the formula:
01.0)log(654321
0
exp)(
432
tatatatataa
t
a
tP
wi
where
a0 = -5674.5359
a1 = 6.3925247
a2 = -9.677843E - 03
a3 = 0.00000062215701
a4 = 2.0747825E - 09
a5 = -9.484024E - 13
a6 = 4.1635019
t = Temperature [K]
Table 113 Inputs for Wet Bulb Temperature Calculation
Input Variable
Air temperature (T
A
) TAAVG1M, see Table 4 on page 22
Dewpoint temperature (T
d
) DPAVG1M, see Table 4 on page 22
Atmospheric pressure (P
A
) QFEAVG1M, see Table 5 on page 23