EasyManuals Logo

Watlow F4T User Manual

Watlow F4T
331 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Watlow F4T 8 Chapter 1 Overview
Outputs
Outputs respond to information provided by a function such as, heat power from the output
of the control loop, driving a digital output based on a profile event, turn a light on or off,
unlocking a furnace door or turning on a buzzer.
More than one output can be assigned to respond to any given function, i.e., more than one
output device could be connected to the heat output of the control block. Another example
(not shown), could use the (internal) output of the alarm function and connect it to any avail-
able real-world output to trigger a flashing light and another real-world output that might be
connected to a siren.
What is a Profile
A profile is a set of instructions consisting of a sequence of steps. When a profile runs, the
controller automatically executes its steps in sequence. The step type determines what ac-
tion the controller performs. Steps can change temperatures and other process values gradu-
ally over time, maintain the temperatures and process values for specific periods, or repeat a
sequence of steps numerous times. At each step the profile can activate or deactivate outputs
that control other equipment. Also a step can have the controller wait for specific conditions
before proceeding such as, waiting for a switch closure and/or a specific process value to be
detected by a sensor.
Data Logging
Controllers equipped with this feature will have the letter [J, K, L or M] in the fifth character
of its part number (see: F4T Ordering Information). Logging can be enabled at any time and is
intended to capture real-time data for a user selectable list of data points. With firmware re-
vision 3.0 and above, several new features are available.
1. User can determine if logged files will be moved automatically and or manually.
2. Destination of the saved file can be directed to internal memory, USB thumb drive, TFTP
server or a Samba shared drive.
3. Based on user choice, files can now be encrypted (filename.enc) for security purposes and
or saved as comma separated values (filename.csv). Creating both file types allows viewing
of the csv file while maintaining the integrity of the encrypted file.
To learn more about configuring these options see the section in this user's guide entitled Set-
ting Up Data Log Files Using Composer.

Table of Contents

Other manuals for Watlow F4T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Watlow F4T and is the answer not in the manual?

Watlow F4T Specifications

General IconGeneral
InputsThermocouple, RTD, mA, V
OutputsRelay, SSR, mA, V
CommunicationEthernet, Modbus RTU
Data LoggingYes
CertificationsCE, UL, cUL, RoHS
Control ModesPID, On/Off
Power Supply100 to 240 VAC
Operating Temperature0 to 50°C
Enclosure RatingIP65
Display4.3 in. (109 mm) color touch panel LCD
Control LoopsUp to 4