Watlow F4T • 146 • Chapter 5 Function Reference
Input Point 7
Set the seventh lowest input value to be scaled. Input values equal to or greater than this,
but less than Input Point 8 are scaled to Output Point 7.
Range: -99,999.000 to 99,999.000
Output Point 7
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 7 and less than Input Point 8.
Range: -99,999.000 to 99,999.000
Input Point 8
Set the eighth lowest input value to be scaled. Input values equal to or greater than this, but
less than Input Point 9 are scaled to Output Point 8.
Range: -99,999.000 to 99,999.000
Output Point 8
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 8 and less than Input Point 9.
Range: -99,999.000 to 99,999.000
Input Point 9
Set the ninth lowest input value to be scaled. Input values equal to or greater than this, but
less than Input Point 10 are scaled to Output Point 9.
Range: -99,999.000 to 99,999.000
Output Point 9
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 9 and less than Input Point 10.
Range: -99,999.000 to 99,999.000
Input Point 10
Set the tenth lowest input value to be scaled. Input values equal to or greater than this are
scaled to Output Point 10.
Range: -99,999.000 to 99,999.000
Output Point 10
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 10.
Range: -99,999.000 to 99,999.000
Offset
Set an adjustment to the final value, added after scaling.
Range: -99,999.000 to 99,999.000