59 / 131
Related Parameters
Rotary Axis
In rotary table configuration, rotary axis is fixed.
Primary Dia
The diameter of the primary tube.
If you select Single or Pair cutting hole type, it is fixed in Tube Cutting Setting.
Auxiliary Dia
The diameter of the auxiliary tube.
The diameter of the auxiliary tube cannot be larger than that of the primary tube.
If you select Auxiliary cutting hole type, it is fixed in Tube Cutting Setting.
Distance
The distance between the central line of the primary tube and the central line of the
auxiliary tube.
Maximum value of distance = ±(Primary diameter - Auxiliary diameter) / 2
Angle
The intersection angle between the primary tube and the auxiliary tube.
Range: [5, 175]°