Maintenance
8460−1/A1
Winterthur Gas & Diesel Ltd.
3/ 5
2. Removal
CAUTION
Damage Hazard: Make sure
that you do not damage
the sealing faces or the
hydraulic pipe.
1) Remove the screws (3, Fig. 3) from the
flange (2).
2) Carefully move the flange (2) away
from the top housing (1).
3) Remove the screws (4, Fig. 4) from the
flange (2).
4) Carefully move the flange (2) away
from the VCU (3).
CAUTION
Injury Hazard: The weight
of the hydraulic pipe is
approximately 21 kg. Use
approved equipment or
sufficient personnel to lift
and move the hydraulic
pipe.
5) Carefully remove the hydraulic pipe (4).
6) Apply protection to the sealing
faces (SF) to prevent damage and
contamination.
Hydraulic Pipe: Removal, Grind, Installation
2016
3SF
III - III
21
WCH02976
II - II
4
3
SF
2
WCH02976
Fig. 3
Fig. 4
1