5.8 Writing Linear Servomotor Parameters
5-21
5
Basic Functions That Require Setting before Operation
Operating Procedure
Use the following procedure to write the motor parameters to the linear encoder.
1.
You can download the motor parameter file to write to the linear encoder from our web
site (http://www.e-mechatronics.com/).
2.
Select Setup - Motor Parameter Scale Write from the menu bar of the Main Window of
the SigmaWin+.
3.
Click the OK Button.
Click the Cancel Button to cancel writing the motor parameters to the linear encoder. The Main Win-
dow will return.
If the write is completed normally, the Motor Parameter Scale Write - File Select Dialog Box will be
displayed.
4.
Click the Ref. Button.
5.
Select the motor parameter file that you downloaded and click the Open Button.