13.4 Utility Function (Fn) Operations on the Panel Operator
13.4.5 Initialize Parameters (Fn005)
13-15
13
Panel Displays and Panel Operator Procedures
13.4.5
Initialize Parameters (Fn005)
Refer to the following section for information on this utility function other than the procedure.
5.1.5 Initializing Parameter Settings on page 5-10
13.4.6
Clear Alarm History (Fn006)
Refer to the following section for information on this utility function other than the procedure.
12.2.5 Clearing the Alarm History on page 12-42
5
Press the UP Key or DOWN Key according to the initial
movement direction of the operation pattern. The
operation will start after the preset waiting time.
Additional Information
Press the MODE/SET Key during operation. The
servo will turn OFF and the Servomotor will stop.
Press the DATA/SHIFT Key for approximately one
second during operation. The display shown for step
2 will appear again.
6
When program jogging has been completed, End will
flash on the display, and then the display shown on the
left will appear again.
Additional Information
Press the MODE/SET Key during operation to turn
OFF the servo and return to the display shown for
step 3.
Press the DATA/SHIFT Key for approximately one
second during operation to return to the display
shown for step 2.
7
Turn the power supply to the SERVOPACK OFF and ON again after you finish program operation.
Step
Panel Display after
Operation
Keys Operation
MODE
/
SET
DATA
/
Step
Panel Display after
Operation
Keys Operation
1
Press the MODE/SET Key to enter Utility Function
Mode.
2 Press the UP Key or DOWN Key to display Fn005.
3
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
4
Press the MODE/SET Key to initialize the parameters.
When the initialization has been completed, donE will
flash on the display, and then the display shown on the
left will appear again.
5
To enable the change to the setting, turn the power supply to the SERVOPACK OFF and ON again
after the initialization of the parameter settings has been completed.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
Step
Panel Display after
Operation
Keys Operation
1
Press the MODE/SET Key to enter Utility Function
Mode.
2 Press the UP Key or DOWN Key to display Fn006.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/