2.1 Ratings and Specifications
2.1.2 Specifications
2-5
Communi-
cations
RS-422A
Communi-
cations
(CN3)
Inter-
faces
Digital Operator (JUSP-OP05A-1-E) and personal computer (with Sig-
maWin+)
1:N
Commu-
nications
Up to N = 15 stations possible for RS-422A port
Axis
Address
Setting
Set with parameters.
USB
Communi-
cations
(CN7)
Interface Personal computer (with SigmaWin+)
Commu-
nica-
tions
Standard
Conforms to USB2.0 standard (12 Mbps).
Displays/Indicators CHARGE indicator and five-digit seven-segment display
Panel Operator Four push switches
Analog Monitor (CN5)
Number of points: 2
Output voltage range: ±10 VDC (effective linearity range: ±8 V)
Resolution: 16 bits
Accuracy: ±20 mV (Typ)
Maximum output current: ±10 mA
Settling time (±1%): 1.2 ms (Typ)
Dynamic Brake (DB)
Activated when a servo alarm or overtravel (OT) occurs, or when the
power supply to the main circuit or servo is OFF.
Regenerative Processing Built-in
Overtravel (OT) Prevention
Stopping with dynamic brake, deceleration to a stop, or coasting to a
stop for the P-OT (Forward Drive Prohibit) or N-OT (Reverse Drive Pro-
hibit) signal
Protective Functions
Overcurrent, overvoltage, low voltage, overload, regeneration error, etc.
Utility Functions
Gain adjustment, alarm history, jogging, origin search, etc.
Safety
Functions
Inputs /HWBB1 and /HWBB2: Base block signals for Power Modules
Output EDM1: Monitors the status of built-in safety circuit (fixed output).
Applicable Stan-
dards
*2
ISO13849-1 PLe (Category 3) and IEC61508 SIL3
Continued on next page.
Continued from previous page.
Item Specification