7.3 Trial Operation for the Servomotor without a Load
7.3.2 Applicable Tools
7-8
Linear Servomotors
7.3.2
Applicable Tools
The following table lists the tools that you can use to perform jogging and the applicable tool
functions.
7.3.3
Operating Procedure
Use the following procedure.
1.
Select Test Run - Jog from the menu bar of the Main Window of the SigmaWin+.
The Jog Operation Dialog Box will be displayed.
2.
Read the warnings and then click the OK Button.
Pn383
Jogging Speed
Setting Range Setting Unit Default Setting When Enabled Classification
0 to 10,000 1 mm/s 50 Immediately Setup
Pn305
Soft Start Acceleration Time
Setting Range Setting Unit Default Setting When Enabled Classification
0 to 10,000 1 ms 0 Immediately Setup
Pn306
Soft Start Deceleration Time
Setting Range Setting Unit Default Setting When Enabled Classification
0 to 10,000 1 ms 0 Immediately Setup
When an absolute encoder is used, you do not need to input the SEN signal. It is always
active.
Speed
Position
Force
Speed
Speed
Information
Tool Function Operating Procedure Reference
Panel Operator Fn002
13.4.2 Jog (Fn002) on page 13-13
Digital Operator Fn002
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
SigmaWin+ Test Run - Jog
Operating Procedure on page 7-8