12.2 Alarm Displays
12.2.6 Resetting Alarms Detected in Option Modules
12-43
12
Maintenance
12.2.6
Resetting Alarms Detected in Option Modules
If any Option Modules are attached to the SERVOPACK, the SERVOPACK detects the pres-
ence and models of the connected Option Modules. If it finds any errors, it outputs alarms.
You can delete those alarms with this operation.
Preparations
Confirm the following condition before you clear alarms that were detected in Option Module.
The parameters must not be write prohibited.
Applicable Tools
The following table lists the tools that you can use to reset Option Module configuration errors
and the applicable tool functions.
Operating Procedure
Use the following procedure.
1.
Select Setup Reset Configuration Error of Option Module from the menu bar of the
Main Window of the SigmaWin+.
The Reset Configuration Error of Option Module Dialog Box will be displayed.
This dialog box will be displayed automatically when you start the SigmaWin+ if there is an error in an
Option Module.
2.
Select the Clear Check Box for the Option Modules from which to clear alarms and the
click the Execute Button.
This operation is the only way to reset alarms for Option Modules. The alarms are not reset
when you reset other alarms or when you turn OFF the power supply to the SERVOPACK.
Always remove the cause of an alarm before you reset the alarm.
Tool Function Reference
Panel Operator Fn014
13.4.19
Reset Option Module Configuration Error
(Fn014)
on page 13-24
Digital Operator Fn014
Σ
-7-Series Digital Operator Operating Manual
(Manual No.: SIEP S800001 33)
SigmaWin+
Setup
Reset Configuration Error of
Option Module
Operating Procedure
on page 12-43
Information
You cannot clear the Error detected detection
result. Remove the Option Module, or check to
see if the Option Module is correctly mounted.