6.15 Initializing the Vibration Detection Level
6.15.2 Applicable Tools
6-94
6.15.2
Applicable Tools
The following table lists the tools that you can use to initialize the vibration detection level and
the applicable tool functions.
6.15.3
Operating Procedure
Use the following procedure.
1.
Select Setup - Initialize Vibration Detection Level from the menu bar of the Main Win-
dow of the SigmaWin+.
2.
Select Pn311: Vibration Detection Sensitivity and Pn310: Vibration Detection Selec-
tions and then click the Detection Start Button.
A setting execution standby mode will be entered.
Tool Function Operating Procedure Reference
Panel Operator Fn01B
13.4.20 Initialize Vibration Detection Level (Fn01B) on
page 13-25
Digital Operator Fn01B
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
SigmaWin+
Setup - Initialize Vibra-
tion Detection Level
6.15.3 Operating Procedure on page 6-94