13.4 Utility Function (Fn) Operations on the Panel Operator
13.4.21 Display SERVOPACK and Servomotor IDs (Fn01E)
13-26
13.4.21
Display SERVOPACK and Servomotor IDs (Fn01E)
This function cannot be executed from the Panel Operator on the SERVOPACK.
13.4.22
Display Servomotor ID from Feedback Option Module
(Fn01F)
This function cannot be executed from the Panel Operator on the SERVOPACK.
13.4.23
Set Absolute Linear Encoder Origin (Fn020)
Refer to the following section for information on this utility function other than the procedure.
5.18.1 Setting the Origin of the Absolute Linear Encoder on page 5-54
Step
Panel Display after
Operation
Keys Operation
1
Press the MODE/SET Key to enter Utility Function
Mode.
2 Press the UP Key or DOWN Key to display Fn020.
3
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
4
Continue pressing the UP Key until 0SET5 is dis-
played.
Note: If you make a mistake during key operations, no_oP will
flash on the display for approximately one second and
then Fn000 will be displayed again.
5
Press the MODE/SET Key to set the origin of the
absolute linear encoder.
When the setting has been completed, donE will flash
on the display, and then the display shown on the left
will appear again.
6
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn020.
7 To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.
MODE
SET
DATA
MODE
/
SET
DATA
/
MODE
SET
DATA
MODE
/
SET
DATA
/