4.3 Wiring the Power Supply to the SERVOPACK
4.3.2 Wiring Procedure for Main Circuit Connector
4-12
You can use a single-phase, 200-V power supply input with the following models.
• SGD7S-R70A, -R90A, -1R6A, -2R8A, -5R5A
If you use a single-phase, 200-VAC power supply input for the SERVOPACK’s main circuit
power supply, set parameter Pn00B to n.1 (Use a three-phase power supply input as a
single-phase power supply input). Refer to the following section for details.
5.3.2 Single-phase AC Power Supply Input/Three-phase AC Power Supply Input Setting on page 5-15
• DC Power Supply Input
If you use a DC power supply input to the SERVOPACK, make sure to set parameter Pn00E
to n.1 (DC power supply input supported) before inputting the power supply. Refer to
the following section for details.
5.3.1 AC Power Supply Input/DC Power Supply Input Setting on page 5-14
4.3.2
Wiring Procedure for Main Circuit Connector
• Required Items
B1/ , B2, B3
Regenerative Resistor termi-
nals
4.3.5 Wiring Regenerative Resistors on page 4-17
For SGD7S-R70A, -R90A, -1R6A, and -2R8A
If the regenerative capacity is insufficient, connect an Exter-
nal Regenerative Resistor between B1/ and B2.
The External Regenerative Resistor is not included. Pur-
chase it separately.
For SGD7S-5R5A
If the internal regenerative resistor is insufficient, remove the
lead or short bar between B2 and B3 and connect an Exter-
nal Regenerative Resistor between B1/ and B2.
The External Regenerative Resistor is not included. Pur-
chase it separately.
1, 2
DC Reactor terminals for
power supply harmonic
suppression
4.3.6 Wiring DC Reactors on page 4-18
These terminals are used to connect a DC Reactor for power
supply harmonic suppression or power factor improvement.
L3,
− None. (Do not connect anything to these terminals.)
Ter mi n a l
Symbols
Ter mi n a l N a me Specifications and Reference
L1C, L2C
Control power supply termi-
nals
270 to 324 VAC, -15% to +10%
B1/
Main circuit power supply
input terminals for DC
power supply input
270 VDC to 324 VDC, -15% to +10%
2
0 VDC
L1, L2, L3,
B2, B3, 1, − None. (Do not connect anything to these terminals.)
Continued from previous page.
Ter mi n a l
Symbols
Ter mi n a l N a me Specifications and Reference
Required Item Remarks
Spring Opener or Flat-
blade Screwdriver
• Spring Opener
SERVOPACK accessory
(You can also use model 1981045-1 from Tyco Electronics Japan G.K.)
• Flat-blade screwdriver
Commercially available screwdriver with tip width of 3.0 mm to 3.5 mm