EasyManua.ls Logo

YASKAWA E-7-Series SGD7S - Initialize Vibration Detection Level (Fn01 B)

YASKAWA E-7-Series SGD7S
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13.4 Utility Function (Fn) Operations on the Panel Operator
13.4.20 Initialize Vibration Detection Level (Fn01B)
13-25
13
Panel Displays and Panel Operator Procedures
13.4.20
Initialize Vibration Detection Level (Fn01B)
Refer to the following section for information on this utility function other than the procedure.
6.15 Initializing the Vibration Detection Level on page 6-93
2
Press the UP Key or DOWN Key to display Fn014.
3
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
4
Press the UP Key or DOWN Key to select the Option
Module to be cleared.
5
Press the MODE/SET Key for approximately one sec-
ond. The display shown at the left will appear.
6
Press the MODE/SET Key again. The alarms in the
Option Module will be cleared.
donE will flash on the display and the display shown
on the left will appear again.
7
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn014.
8
To enable the change to the setting, turn the power supply to the SERVOPACK OFF and ON again
after clearing detected Option Module alarms has been completed.
Step
Panel Display after
Operation
Keys Operation
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
Step
Panel Display after
Operation
Keys Operation
1
Press the MODE/SET Key to enter Utility Function
Mode.
2 Press the UP Key or DOWN Key to display Fn01b.
3
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
4
(Flashing)
Press the MODE/SET Key for approximately one sec-
ond. The display shown on the left will flash and the
vibration level will be detected and updated.
Note: 1. Operate the SERVOPACK with the references that
will be used for actual operation.
2. If the Servomotor operates at 10% or less of the
maximum speed, Error will be displayed.
5
Wait for a period of time and then press the MODE/
SET Key again to complete vibration detection and
updating the setting. This will enable the setting. If the
setting is completed normally, donE will be displayed.
If there was an error in making the setting, Error will be
displayed.
6
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn01b.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/

Table of Contents

Related product manuals