EasyManua.ls Logo

YASKAWA E-7-Series SGD7S - Page 298

YASKAWA E-7-Series SGD7S
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.6 Convenient Function to Use during Trial Operation
7.6.3 Test without a Motor
7-29
7
Trial Operation and Actual Operation
Restrictions
The following functions cannot be used during the test without a motor.
Regeneration and dynamic brake operation
Brake output signal
Refer to the following section for information on confirming the brake output signal.
9.2.3 I/O Signal Monitor on page 9-5
Items marked with “×” in the following utility function table
SigmaWin+ Panel Operator or Digital Operator Executable?
Reference
Menu Bar
Button
SigmaWin+ Function
Name
Fn No. Utility Function Name
Motor Not
Connected
Motor
Connected
Setup
Origin Search Fn003 Origin Search 
page 7-25
Resetting the Abso-
lute Encoder
Fn008
Reset Absolute
Encoder
×
page 5-52
Speed/Torque Refer-
ence Offset Adjust-
ment
Fn009
Autotune Analog
(Speed/Torque) Refer-
ence Offset

page 6-22,
page 6-38
Fn00A
Manually Adjust Speed
Reference Offset

page 6-22
Fn00B
Manually Adjusting the
Torque Reference Off-
set

page 6-38
Analog Monitor Out-
put Adjustment
Fn00C
Adjust Analog Monitor
Output Offset

page 9-8
Fn00D
Adjust Analog Monitor
Output Gain

page 9-8
Motor Current Detec-
tion Offset Adjust-
ment
Fn00E
Autotune Motor Cur-
rent Detection Signal
Offset
×
page 6-97
Fn00F
Manually Adjust Motor
Current Detection Sig-
nal Offset
×
Parameter Write Pro-
hibition Setting
Fn010
Write Prohibition Set-
ting

page 5-7
Multiturn Limit Setting Fn013
Multiturn Limit Setting
after Multiturn Limit
Disagreement Alarm
×
page 6-80
Reset Configuration
Error of Option Mod-
ule
Fn014
Reset Option Module
Configuration Error

page 12-43
Initializing the Vibra-
tion Detection Level
Fn01B
Initialize Vibration
Detection Level
× ×
page 6-93
Setting the Origin of
the Absolute Linear
Encoder
Fn020
Set Absolute Linear
Encoder Origin
×
page 5-54
Reset Motor Type
Alarm
Fn021
Reset Motor Type
Alarm

Software Reset Fn030 Software Reset 
page 6-91
Polarity Detection Fn080 Polarity Detection × ×
page 5-27
Tuning-less Level
Setting
Fn200
Tuning-less Level Set-
ting
× ×
page 8-15
Easy FFT Fn206 Easy FFT × ×
page 8-85
Parameter
Initialize Servo
*
Fn005 Initialize Parameters 
page 5-10

Table of Contents

Related product manuals