8.6 Autotuning without Host Reference
8.6.7 Related Parameters
8-34
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Pn147 Model Following Control Speed Feedforward Compensation Yes
Pn160 Anti-Resonance Control-Related Selections Yes
Pn161 Anti-Resonance Frequency Yes
Pn163 Anti-Resonance Damping Gain Yes
Pn531 Program Jogging Travel Distance No
Pn533 Program Jogging Movement Speed for Rotary Servomotor No
Pn585 Program Jogging Movement Speed for Linear Servomotor No
Pn534 Program Jogging Acceleration/Deceleration Time No
Pn535 Program Jogging Waiting Time No
Pn536 Program Jogging Number of Movements No
Parameter Name Automatic Changes