8.7 Autotuning with a Host Reference
8.7.4 Operating Procedure
8-39
8
Tuning
9.
Turn ON the servo, enter a reference from the host controller, and then click the Start
tuning Button.
10.
Confirm safety around moving parts and click the Yes Button.
The motor will start operating and tuning will be executed.
Vibration that occurs during tuning will be detected automatically and suitable settings will be made
for that vibration. When the settings have been completed, the indicators for the functions that were
used will light at the lower left of the dialog box.
11.
When tuning has been completed, click the Finish Button.
The results of tuning will be set in the parameters and you will return to the Tuning Dialog Box.
This concludes the procedure.