12.2  Alarm Displays
 12.2.1  List of Alarms
12-9
A.C21 Polarity Sensor Error
An error occurred in the 
polarity sensor.
Gr.1 No L H L
A.C22
Phase Information Dis-
agreement
The phase information does 
not match.
Gr.1 No L H L
A.C50 Polarity Detection Failure The polarity detection failed. Gr.1 No L H L
A.C51
Overtravel Detected 
during Polarity Detection
The overtravel signal was 
detected during polarity 
detection.
Gr.1 Yes L H L
A.C52
Polarity Detection Not 
Completed
The servo was turned ON 
before the polarity was 
detected.
Gr.1 Yes L H L
A.C53
Out of Range of Motion for 
Polarity Detection
The travel distance exceeded 
the setting of Pn48E (Polarity 
Detection Range).
Gr.1 No L H L
A.C54
Polarity Detection Failure 
2
The polarity detection failed. Gr.1 No L H L
A.C80
Encoder Clear Error or 
Multiturn Limit Setting 
Error
The multiturn data for the 
absolute encoder was not 
correctly cleared or set.
Gr.1 No L H L
A.C90
Encoder Communications 
Error
Communications between 
the encoder and SERVO-
PACK is not possible.
Gr.1 No L H L
A.C91
Encoder Communications 
Position Data Acceleration 
Rate Error
An error occurred in calculat-
ing the position data of the 
encoder.
Gr.1 No L H L
A.C92
Encoder Communications 
Timer Error
An error occurred in the com-
munications timer between 
the encoder and SERVO-
PACK.
Gr.1 No L H L
A.CA0 Encoder Parameter Error
The parameters in the 
encoder are corrupted.
Gr.1 No L H L
A.Cb0 Encoder Echoback Error
The contents of communica-
tions with the encoder are 
incorrect.
Gr.1 No L H L
A.CC0
Multiturn Limit Disagree-
ment
Different multiturn limits have 
been set in the encoder and 
the SERVOPACK.
Gr.1 No L H L
A.CF1
Reception Failed Error in 
Feedback Option Module 
Communications
Receiving data from the 
Feedback Option Module 
failed.
Gr.1 No L H L
A.CF2
Timer Stopped Error in 
Feedback Option Module 
Communications
An error occurred in the timer 
for communications with the 
Feedback Option Module.
Gr.1 No L H L
A.d00
Position Deviation Over-
flow
The setting of Pn520 (Exces-
sive Position Deviation Alarm 
Level) was exceeded by the 
position deviation while the 
servo was ON.
Gr
.1 Yes L L H
A.d01
Position Deviation Over-
flow Alarm at Servo ON
The servo was turned ON 
after the position deviation 
exceeded the setting of 
Pn526 (Excessive Position 
Deviation Alarm Level at 
Servo ON) while the servo 
was OFF.
Gr.1 Yes L L H
Continued from previous page.
Alarm 
Number
Alarm Name Alarm Meaning
Servo-
motor 
Stop-
ping 
Method
Alarm 
Reset 
Possi-
ble?
Alarm Code 
Output
ALO1 ALO2 ALO3