EasyManua.ls Logo

YASKAWA E-7-Series SGD7S - Page 552

YASKAWA E-7-Series SGD7S
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.2 Parameter Recording Table
14-38
Pn503 10
Speed Coincidence Detec-
tion Signal Output Width
Immediately
Pn506 0
Brake Reference-Servo
OFF Delay Time
Immediately
Pn507 100
Brake Reference Output
Speed Level
Immediately
Pn508 50
Servo OFF-Brake Com-
mand Waiting Time
Immediately
Pn509 20
Momentary Power Interrup-
tion Hold Time
Immediately
Pn50A 2100 Input Signal Selections 1 After restart
Pn50B 6543 Input Signal Selections 2 After restart
Pn50C 8888 Input Signal Selections 3 After restart
Pn50D 8888 Input Signal Selections 4 After restart
Pn50E 3211 Output Signal Selections 1 After restart
Pn50F 0000 Output Signal Selections 2 After restart
Pn510 0000 Output Signal Selections 3 After restart
Pn512 0000
Output Signal Inverse Set-
tings
After restart
Pn513 0000
Output Signal Inverse Set-
tings 2
After restart
Pn514 0000 Output Signal Selections 4 After restart
Pn515 8888 Input Signal Selections 6 After restart
Pn516 8888 Input Signal Selections 7 After restart
Pn517 0654 Output Signal Selections 5 After restart
Pn51B 1000
Motor-Load Position Devia-
tion Overflow Detection
Level
Immediately
Pn51E 100
Position Deviation Over-
flow Warning Level
Immediately
Pn520 5242880
Position Deviation Over-
flow Alarm Level
Immediately
Pn522 7
Positioning Completed
Width
Immediately
Pn524
1073741
824
Near Signal Width Immediately
Pn526 5242880
Position Deviation Over-
flow Alarm Level at Servo
ON
Immediately
Pn528 100
Position Deviation Over-
flow Warning Level at Servo
ON
Immediately
Pn529 10000
Speed Limit Level at Servo
ON
Immediately
Pn52A 20
Multiplier per Fully-closed
Rotation
Immediately
Pn52B 20 Overload Warning Level Immediately
Pn52C 100
Base Current Derating at
Motor Overload Detection
After restart
Pn52D 50 Reserved parameter
Pn52F 0FFF Monitor Display at Startup Immediately
Pn530 0000
Program Jogging-Related
Selections
Immediately
Pn531 32768
Program Jogging Travel
Distance
Immediately
Continued from previous page.
Parameter
No.
Default
Setting
Name
When
Enabled

Table of Contents

Related product manuals