2.3 External Dimensions
2.3.2 SERVOPACK External Dimensions
2-12
•
Three-phase, 200 VAC: SGD7S-2R8A
•
Three-phase, 200 VAC: SGD7S-3R8A, -5R5A, and -7R6A
•
Three-phase, 200 VAC: SGD7S-120A
160
168
8
40
170
18
168
5
2
×
M4
40
5
(75)
(4)
Ground
terminals
2 × M4
160 ±0.5 (mounting pitch)
Exterior
20 ±0.5 (mounting pitch)
Mounting Hole Diagram
Unit: mm
Approx. mass: 1.0 kg
Two sets of terminals
160
168
8
70
180
18
70
6
168
3
×
M4
5
(75)
(4)
Ground
terminals
2 × M4
160 ±0.5 (mounting pitch)
Exterior
58 ±0.5 (mounting pitch)
Mounting Hole Diagram
Unit: mm
Approx. mass: 1.6 kg
Two sets of terminals
160
168
8
90
180
18
168
5
3
×
M4
90
12.5
5
(75)
(4)
Two sets of terminals
Ground
terminals
2 × M4
160 ±0.5 (mounting pitch)
Exterior
80 ±0.5 (mounting pitch)
Mounting Hole Diagram
Unit: mm
Approx. mass: 2.2 kg