11 Appendix
11.2.1 List of Parameters
11-10
Pn305 2
Soft Start Acceleration
Time
0 to 10000 1 ms 0 Immediately Setup −−
Pn306 2
Soft Start Deceleration
Time
0 to 10000 1 ms 0 Immediately Setup −−
Pn310
2
Vibration Detection
Switch
0000 to
0002
0000 Immediately Setup −−
Pn311 2
Vibration Detection
Sensibility
50 to 500 1% 100 Immediately Tuning 9.10
Pn312 2 Vibration Detection Level 0 to 5000
1 min
-1
50 Immediately Tuning 9.10
Pn324 2
Moment of Inertia
Calculating Start Level
0 to 20000 1% 300 Immediately Setup 8.3.2
Pn401 2
Torque Reference Filter
Time Constant
0 to 65535
0.01
ms
100 Immediately Tuning 8.9.3
Pn402 2 Forward Torque Limit 0 to 800 1% 800 Immediately Setup 7.5.1
Pn403 2 Reverse Torque Limit 0 to 800 1% 800 Immediately Setup 7.5.1
Pn406 2 Emergency Stop Torque 0 to 800 1% 800 Immediately Setup 7.3.3
Pn407 2
Speed Limit during
Torque Control
0 to 10000
1 min
-1
10000 Immediately Setup −−
(cont’d)
Parameter
No.
Size Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile
Reference
Section
Vibration Detection Selection
Reference
Section
0 Does not detect vibration.
9.10
1 Outputs warning (A.911) when vibration is detected.
2 Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents

Related product manuals