11 Appendix
11.2.1 List of Parameters
11-12
Pn460
2
Notch Filter Adjustment
Switch
0000 to
0101
0101 Immediately Tuning
8.2.1,
8.3.1,
8.5.1
Pn506 2
Brake Reference
-
Servo OFF Delay Time
0 to 50 10 ms 0 Immediately Setup 7.3.4
Pn507 2
Brake Reference Output
Speed Level
0 to 10000
1 min
-1
100 Immediately Setup 7.3.4
Pn508 2
Waiting Time for Brake
Signal When Motor
Running
10 to 100 10 ms 50 Immediately Setup 7.3.4
Pn509 2 Reserved (Do not change.) 20 −−
Pn51E 2
Excessive Position Error
Warning Level
10 to 100 1% 100 Immediately Setup 10.3.1
Pn520 4
Excessive Position Error
Alarm Level
1 to
1073741823
1
refer-
ence
unit
5242880
Immediately Setup
8.1.4,
10.2.1
Pn52B 2 Overload Warning Level 1 to 100 1% 20 Immediately Setup 7.3.6
Pn52C 2
Derating of Base Current
at Detecting Overload of
Motor
10 to 100 1% 100 After restart Setup 7.3.6
(cont’d)
Parameter
No.
Size Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile
Reference
Section
Notch Filter Adjustment Selection 1
0 Does not adjust 1st step notch filter automatically using utility function.
1 Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0 Does not adjust 2nd step notch filter automatically using utility function.
1 Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit