Parameter Details
12
12.10 n: Special Adjustment
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 1015
0 : Disabled
1 : Enabled Only when Rotating FWD
2 : Enabled Only when Rotating REV
Note:
When n3-23 = 1, 2, the drive enables overexcitation only in the direction of motor rotation in which a regenerative load is applied. Increased
motor loss can decrease ov [Overvoltage] faults.
n4: Adv Open Loop Vector Tune
To make special adjustments for Advanced Open Loop [A1-02 = 4] (AOLV) control, note these items:
Do Rotational Auto-Tuning first.
When there is a load, applications must stay constant around zero speed in AOLV control. If the application will not
stay constant around zero speed, set A1-02 = 3 [Closed Loop Vector].
The tolerance of regenerative torque at low speeds decreases in AOLV control. When regenerative torque is
necessary in the low speed range, set A1-02 = 3.
If you operate the drive at a frequency lower than n4-70 [Speed Command Comp @ Low Freq] (default setting:
1.00 Hz), the motor can rotate at a frequency that is approximately 1/2 of the n4-70 setting. Set E1-09 [Minimum
Output Frequency] > 0 to not let the motor to rotate at a lower frequency than the n4-70 setting. When the
frequency reference E1-09, the drive output will turn OFF.
n4-60: Motoring Low Speed Comp Gain
No.
(Hex.)
Name Description
Default
(Range)
n4-60
(1B80)
Motoring Low Speed Comp
Gain
Sets a compensation gain to improve the control qualities for motoring loads in the low speed range.
100.0%
(50.0 - 200.0%)
Note:
To improve torque accuracy in the motoring direction when running at low speeds, either perform only Stationary Auto-Tuning for Line-to-
Line Resistance, or increase the setting value in 5% increments. The recommended setting is 100% to 120%.
If the output frequency changes when you operate at low speeds, do Stationary Auto-Tuning for Line-to-Line Resistance only. If it is not
better, increase this parameter in 10% increments. The recommended setting is 50% to 100%.
n4-61: Low Speed Comp Frequency Level
No.
(Hex.)
Name Description
Default
(Range)
n4-61
(1B81)
Low Speed Comp Frequency
Level
Sets a frequency at which the settings n4-60 [Motoring Low Speed Comp Gain] and n4-62 [Regen
Low Speed Comp Gain] are enabled. When the output frequency < n4-61, the drive adjusts the torque
to agree with the settings for n4-60 and n4-62. Usually it is not necessary to change this setting.
6.00 Hz
(0.50 - 12.00 Hz)
n4-62: Regen Low Speed Comp Gain
No.
(Hex.)
Name Description
Default
(Range)
n4-62
(1B82)
Regen Low Speed Comp
Gain
Sets a compensation gain to improve the control qualities for regenerative loads in the low speed
range.
100.0 %
(50.0 - 500.0%)
Note:
If you do not apply a regenerative load when you operate at low speeds, do stationary Auto-Tuning for Line-to-Line Resistance only. If this
does not make it better, increase the setting value in 5% increments. The recommended setting is 100% to 150%. If you set this parameter too
high, the drive will detect CF [Control Fault] at stop.
n4-63: Speed EstimateResponse@High Freq
No.
(Hex.)
Name Description
Default
(Range)
n4-63
(1B83)
Speed
EstimateResponse@High
Freq
Sets the responsiveness of the speed estimation in high speed ranges, where the output frequency is
n4-67 [Estimate Gain Switchover Freq].
60.0
(0.1 - 300.0)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV