8.4 Replace Cooling Fans and Circulation Fans
434 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
8.4 Replace Cooling Fans and Circulation Fans
CAUTION! Injury to Personnel. Some fan units are not easily accessible from a standing position. Make sure that you can safely
and comfortably remove and replace the fan. If you try to remove a fan that you cannot easily access, the fan unit can fall and cause
minor to moderate injury.
NOTICE: Use the instructions in this manual to replace the cooling fans. When you do maintenance on the fans, replace all the fans
to increase product life. If you install the fans incorrectly, it can cause damage to the drive.
Cooling Fans and Circulation Fans by Drive Model
Table 8.11 Cooling Fans and Circulation Fans (Three-Phase 200 V Class)
Model Cooling Fan Circulation Fan Procedure Ref.
2004 - 2012 - - - -
2018, 2021 1 - Procedure A 434
2030, 2042 2 - Procedure B 436
2056 - 2082 2 - Procedure C
439
2110 - 2211 2 - Procedure D
441
2257 - 2313 2 - Procedure E
443
2360, 2415 3 1 Procedure F 446
Table 8.12 Cooling Fans and Circulation Fans (Three-Phase 400 V Class)
Model Cooling Fan Circulation Fan
Circuit Board Cooling
Fan
Procedure Ref.
4002 - 4005 - - - - -
4007 - 4012 1 - - Procedure A 434
4018, 4023 2 - - Procedure B 436
4031 - 4060 2 - - Procedure C
439
4075 - 4168
T103 - T168
2 - - Procedure D
441
4208 - 4302
T208 - T302
2 - - Procedure E
443
4371
T371
2 1 - Procedure F 446
4414
T414
3 1 - Procedure F 446
4477 - 4605
T477 - T605
2 1 2 Procedure G 452
4720
T720
3 1 2 Procedure H 460
Fan Replacement (Procedure A)
DANGER! Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before servicing,
disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal capacitor
stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage decreases below 50
Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make sure that the drive is safe. If
you do work on the drive when it is energized, it will cause serious injury or death from electrical shock.
CAUTION! Burn Hazard. Do not touch a hot drive heatsink. De-energize the drive, wait for a minimum of 15 minutes, then make
sure that the heatsink is cool before you replace the cooling fans. If you touch a hot drive heatsink, it can burn you.
NOTICE: Use the instructions in this manual to replace the cooling fans. When you do maintenance on the fans, replace all the fans