EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
1078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical Installation
3
3.9 Braking Resistor Installation
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 131
Figure 3.71 Install a Braking Resistor Unit: LKEB-Type
Install a Braking Unit Connection: CDBR-Type
To install a CDBR-type braking unit, connect terminal +3 on the drive to terminal + on the braking unit, and connect
terminal - on the drive to terminal - on the braking unit. Terminal +2 on the drive is not necessary for CDBR-type
braking unit connections.
Set L8-55 = 0 [Internal DB TransistorProtection = Disable].
Note:
To install a CDBR-type braking unit to the drive models 2004 to 2138 and 4002 to 4168 that have a built-in braking transistor, connect
drive terminal B1 to terminal + on the braking unit.
A junction terminal is necessary to connect a braking unit (CDBR-series) to drive models 2169, 2211, 4140, 4168, T140, and T168. To wire
the braking unit, install a junction terminal that can connect to wires in the range specified for the drive, peripheral devices, and options.
This table shows recommended junction terminals. Contact Yaskawa or your nearest sales representative for more information about
selection and installation of the junction terminal.
Drive Model
Junction Terminal Model
Manufacturer: Mibu Denki Industrial Co., Ltd.
2169, 4140, 4168, T140, T168 DTK-200N × 2P
*1
2211 DTK-300N × 2P
*1
*1 The junction terminal must have two or more poles.
Figure 3.72 Install a Braking Unit: CDBR-Type/Braking Resistor Unit: LKEB-Type
Braking Unit Connection Wire Gauge (CDBR-Type)
To comply with IP20 when you connect the braking unit (CDBR-type) to drive models 2257 to 2415, 4208 to 4720, or
T208 to T720, refer to Table 3.18, Table 3.19, and Table 3.20 to select the wires.