EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
1078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
7
7.3 List of Fault, Minor Fault, Alarm, and Error Codes
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 353
7.3 List of Fault, Minor Fault, Alarm, and Error Codes
Table 7.2 shows the possible fault, minor fault, alarm, and error codes.
The display codes are in alphabetical order. Search the table for the code shown on the keypad, and identify its causes
and possible solutions.
Note:
The number in parentheses adjacent to the code in the table identifies the fault code or minor fault code (hex. number) that was read during
MEMOBUS/Modbus communications.
Example: AEr (0032)
Table 7.2 List of Fault, Minor Fault, Alarm, and Error Codes
Display (Hex.) Name ALM LED Type Ref.
AEr (0032) Station Address Setting Error Flashing Alarm 390
bAT (0085) Keypad Battery Low Voltage Flashing Alarm 390
bAT (0402) Keypad Battery Low Voltage Illuminated Fault 359
bb (0008) Baseblock Flashing Alarm 390
bCE (008A) Bluetooth Communication Error Flashing Alarm 390
bCE (0416) Bluetooth Communication Fault Illuminated Fault 359
boL (0045) Braking Transistor Overload Flashing Alarm 390
boL (004F) BrakingTransistor Overload Fault Illuminated Fault 359
bUS (0015) Option Communication Error Flashing Alarm 390
bUS (0022) Option Communication Error Illuminated Fault 359
bUSy Busy - Not an alarm. 391
CALL (001D) Serial Comm Transmission Error Flashing Alarm 391
CE (0014) Modbus Communication Error Flashing Alarm 391
CE (0021) Modbus Communication Error Illuminated Fault 359
CF (0025) Control Fault Illuminated Fault 360
CoF (0046) Current Offset Fault Illuminated Fault 360
CP1 (0087) Comparator 1 Limit Error Flashing Alarm 391
CP1 (0414) Comparator 1 Limit Error Illuminated Fault 360
CP2 (0088) Comparator 2 Limit Error Flashing Alarm 392
CP2 (0415) Comparator 2 Limit Error Illuminated Fault 361
CPF00 Control Circuit Error Illuminated Fault 361
CPF01 Control Circuit Error Illuminated Fault 361
CPF02 (0083)
CPF03 (0084)
Control Circuit Error Illuminated Fault 361, 361
CPF06 (0087) Control Circuit Error (EEPROM memory Data Error) Illuminated Fault 361
CPF07 (0088)
CPF08 (0089)
Control Circuit Error Illuminated Fault 361, 362
CPF10 (009B) - CPF14 (008F) Control Circuit Error Illuminated Fault 362 - 362
CPF16 (0091) - CPF23 (0098) Control Circuit Error Illuminated Fault 362, 363
CPF24 (0099) Control Circuit Error (Drive Unit Signal Fault) Illuminated Fault 363
CPF26 (009B) - CPF39 (00A8) Control Circuit Error Illuminated Fault 363, 365
CPyE Error Writing Data - Backup Function Runtime Error 412
CrST Remove RUN Command to Reset Flashing Not an alarm. 392
CSEr Control Mode Mismatch - Backup Function Runtime Error 412
CyC (0033) MECHATROLINK CommCycleSettingErr Flashing Alarm 392