Parameter Details
12
12.11 o: Keypad-Related Settings
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 1047
0 : Disabled
The drive will not detect EP24v [External Power 24V Supply] if the main circuit power supply voltage decreases. The
[Ready] light on the LED Status Ring flashes quickly to identify that drive operation is not possible.
1 : Enabled
The drive detects EP24v when the main circuit power supply voltage decreases.
Note:
A minor fault signal is not output from H2-xx = 10 [MFDO Function Selection = Alarm].
o2-27: bCE Detection Selection
No.
(Hex.)
Name Description
Default
(Range)
o2-27
(1565)
bCE Detection Selection
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in Bluetooth
Mode.
3
(0 - 4)
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
o3: Copy Function
o3 parameters set the operation of the parameter backup function.
o3-01: Copy Keypad Function Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-01
(0515)
Copy Keypad Function
Selection
Sets the function that saves and copies drive parameters to a different drive with the keypad.
0
(0 - 4)
0 : Copy Select
1 : Backup (drive keypad)
The parameter setting values are read from the drive and saved in the keypad.
2 : Restore (keypad drive)
Copies the parameter setting values saved in the keypad to a different drive.
3 : Verify (check for mismatch)
Makes sure that the parameter setting values in the drive agree with the parameters saved in the keypad.
4 : Erase (backup data of keypad)
Deletes the parameter setting values saved in the keypad.
o3-02: Copy Allowed Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-02
(0516)
Copy Allowed Selection
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive
keypad)].
0
(0, 1)
Note:
When you select [Parameter Backup] on the keypad menu screen to do the backup function, the drive automatically sets o3-02 = 1.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV