4.6 Keypad Operation
198 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
4. Push or to select [Fault Log], then push .
5. Push or to show the fault history you will examine.
Auto-Tuning the Drive
Auto-Tuning uses motor characteristics to automatically set drive parameters.
Refer to the motor nameplate or the motor test report for the necessary information for Auto-Tuning.
Figure 4.12 Motor Nameplate (Example)
WARNING! Sudden Movement Hazard. Before you do Auto-Tuning, remove all personnel and objects from the area around the
drive, motor, and load. The drive and motor can start suddenly during Auto-Tuning and cause serious injury or death.
WARNING! Electrical Shock Hazard. During Auto-Tuning, the motor will receive high voltage when the motor is stopped. Do not
touch the motor until Auto-Tuning is complete. If you touch a motor that is energized, it can cause serious injury or death.
WARNING! Sudden Movement Hazard. Before you do Rotational Auto-Tuning, disconnect the load from the motor. The load can
move suddenly and cause serious injury or death.
This procedure shows how to do Rotational Auto-Tuning.
1. Push (Home) to show the HOME screen.
Note:
When the drive is in HOME Mode, the screen shows [Home] in the upper right-hand corner of the screen.
If the screen does not show [Home] for , push (Back), and then push to show [Home].
2. Push (Menu).